Hoppa till innehåll
Free shipping over SEK 3,000 excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The camera pinpoints the suspect, the measurement probes confirm the faultThe display shows three values simultaneously – exactly as many as you needDon’t look for a value, look for what deviates from its neighborsThe laser dot is not what you measure, it only indicates the center of the measurement spotA calibration certificate doesn’t prove the measurement is correct, only that the instrument isn’t wrongMultimeter with thermal imaging camera — the most important measurement is the one you make before opening the cabinetIR Thermometer with Thermocouple Input — Infrared Always Measures a Surface, Never What Lies Beneath ItAdjustable Emissivity 0.10–1.00 — Why Your IR Thermometer Gives Inaccurate Readings on Shiny MetalIR thermometer with 50:1 optics — at a distance of two meters, an 8:1 thermometer measures an area the size of a dinner plateExtech IR267 mini IR thermometer 12:1 with type K input up to 600 °C: When 903 kr is enough for surface temperature, core temperature AND air temperature in ONE compact bodyVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%The camera pinpoints the suspect, the measurement probes confirm the faultThe display shows three values simultaneously – exactly as many as you needDon’t look for a value, look for what deviates from its neighborsThe laser dot is not what you measure, it only indicates the center of the measurement spotA calibration certificate doesn’t prove the measurement is correct, only that the instrument isn’t wrongMultimeter with thermal imaging camera — the most important measurement is the one you make before opening the cabinetIR Thermometer with Thermocouple Input — Infrared Always Measures a Surface, Never What Lies Beneath ItAdjustable Emissivity 0.10–1.00 — Why Your IR Thermometer Gives Inaccurate Readings on Shiny MetalIR thermometer with 50:1 optics — at a distance of two meters, an 8:1 thermometer measures an area the size of a dinner plateExtech IR267 mini IR thermometer 12:1 with type K input up to 600 °C: When 903 kr is enough for surface temperature, core temperature AND air temperature in ONE compact body

Close-Focus IR with 2.5 mm Spot Size: When Component Temperature Needs Measuring — Not the Whole Board’s

Published July 2, 2026 at 18:28

Every electronics technician knows the exact same frustrating scenario: a device fails during operation, gets hot after a few minutes, and you suspect that a specific component on the circuit board is overheating. With a standard IR thermometer, you aim the beam at the board — but the reading displays an average temperature across the entire area seen by the IR thermometer’s optics. At a distance of 30 cm with 12:1 optics, the measurement spot covers 25 mm, which may include the overheating component and a dozen other components, capacitors, a ground plane, and perhaps part of the heat sink. The average temperature gives you no useful information. You need to measure that exact specific component — and that requires an entirely different type of IR thermometer.

What ”close-focus” actually means

The CIR8855 close-focus IR thermometer is built around optics tuned for measurement at very short distances. At a focal point 18 mm from the lens, the measurement spot is just 2.5 mm in diameter — precisely the right size to focus on an individual SMD component, a TO-220 power transistor, an integrated circuit, or a thin trace. Outside this distance, the measurement spot blurs — the close-focus optics are only sharp within their narrow operating window, which is the core design philosophy behind the instrument.

CIR8855 närfokus-IR-termometer med dubbel laser för 2,5 mm mätfläck

Why dual laser beams are critical

A unique challenge with IR thermometers is that infrared radiation is invisible to the human eye. Without visual targeting, you don’t know exactly where the measurement spot is located. Most IR thermometers have a single laser beam that marks the center of the measurement spot — but the actual size of the spot remains guesswork for the operator.

The CIR8855 solves this with dual laser beams calibrated to coincide (converge) precisely at the 18 mm focal point. When you see a single red dot on the workpiece, you are at the correct focal distance and the measurement spot is exactly 2.5 mm. If you see two separate dots, you are out of focus — simply move either closer or further away until they merge. This simple visual cue eliminates one of the most common sources of measurement error in IR thermometers.

Where close-focus optics make a real difference

Electronic service diagnostics: Temperature measurement of individual components during operation. An overheating driver transistor on an H-bridge, a voltage regulator operating at the limit of its thermal capacity, an integrated circuit with an internal short circuit that only manifests as abnormal heat — all of these require component-level measurement that a standard IR thermometer simply cannot deliver.

R&D and prototyping: During thermal verification testing in product development, the ability to measure individual component temperatures is vital for calculating safety margins against each component’s specified Tj_max. A two-degree difference can determine lifetime calculations for the entire product.

Electric motors and control electronics: Temperature of specific windings, commutators, electronic commutators in variable frequency drives — the critical measurement points are small relative to the unit as a whole.

Appliance and electronic equipment repair: When diagnostics point to a specific section of an electronic control circuit — fuses, TRIACs, MOSFETs — you want to quickly verify which one is running hot. A thermal imaging camera is a more expensive solution; close-focus IR offers direct point-and-measure diagnostics.

PCB testing in production: During final assembly testing, critical components (power supplies, clock generators, power stages) can be verified via a quick thermal measurement — often faster and more cost-effective than full functional testing.

PCB labs and education: Electronics students quickly grasp the relationship between voltage, current, and power dissipation when they can measure individual component temperatures in real time.

What you get for your money

Close-focus optics with a 2.5 mm measurement diameter at an 18 mm focal distance, dual converging laser beams for accurate distance indication, backlit LCD display, and a temperature measurement range up to several hundred degrees (typically sufficient for electronics applications where critical components may reach up to 200 °C, but rarely higher).

1 470 kronor is an investment that an individual electronics technician or a small service lab recoups on a single avoided diagnostic headache. For a tech-oriented hobbyist or student, it provides access to a professional measurement method that makes diagnostics possible without eating into the profitability of the project itself.

Learn more: CIR8855 close-focus IR thermometer in the shop →